Provides ventilation to overdrives and mining stubs
- No power source required
- Prevents gas build up when main ventilation is lost
- Adaptable to all vent tube sizes
- Can incorporate dust suppression additives
- Patented Product
Placed inline with existing vent tubes to keep ventilation of stubs and headings when main ventilation or aux fan stopped.
Proven results:
- Vent when from 1.2 & 2.3m3 in A & B Hdg with just bag hung, then with Ventronic in line in each heading it increased to 2.72 & 3.3m3.
- With Ventronic running reduced general body concentrations from 1.2% to <0.5% CH4